ADD:Yanqiao Economic Zone,
Huishan District, Wuxi, China
|
TEL:86-510-83570269
86-13806174330 |
FAX:86-510-83570269 |
P.C:214174 |
MAIL:globewx@126.com |
|
|
|
|
|
|
|
|
DT830B
规 格:入门型数字万用表
产品备注:直流电压、交流电压、直流电流、电阻、二极管、三极管
产品类别:数字万用表
产 品 说 明
3 1/2 数字液晶屏,最大显示值1999
·低电压符号显示
·过载保护
·二极管和三极管测量
-------------------------------------------------------
[功能]---------[量程]---------[准确度]
直流电压: 200mV-1000V 【±(0.5%+2dgt)】
交流电压: 200-750V 【±(1.2%+10dgt)】
直流电流: 200uA-10A【±(1.0%+2dgt)】
-- 电 阻: 200Ω-2MΩ 【±(0.8%+2dgt)】
二 极 管: 有
三 极 管: 有
电源供应:6F22型9V电池
显示尺寸: 16×48mm
最大显示: 1999
外形尺寸: 126×70×24mm
-- 重 量:150g
标准附件: 表笔、说明书、保修卡
颜色选择: 标准黑、柠檬黄 |
|
|
|
GLB-360TRD
- This instrument is portable multitester designated for measurement of weak current circuits.
- Panel face protection cover which serves also as a stand is employed.
- Our technology has made it possible to measure high resistance (up to maximum 200mΩ) with low voltage.
- Band meter of drop shock type with high sensitivity has beer employed.
- Overload protection circuit up to maximum 230V is provided.
- DCV=O.1m/O.25/2.5/IO/250v ±3%f.s. 1000±5%f.s.
- ACV=10/50/250v±4%f.s. 1000v±5%f.s.
- DCV=50μ/2.5m/25m/0.25A±3%f.s.
- Ω=2k/20k2M+3% of arc. 200M±5% of arc.
- C=10μF
- dB=-10dB-+62dB
- L1=1.5μ/150μ/15m/150mA
- hFE=0-1000
- Power source=R6(l.5V)X2
- Size=160-128X41mm
- Weight=320g
- Box:GTY:40PCS N.W.:14KGS G.W.:15KGS M:48*33*28cm |
|
|
|
GLB-360TRNP
- Range DCV=0.1/0.5/2.5/10/50/250/1000V
- ACV=lO/50/250/1OOOV
- DCmA=0.05/2.5/25/250mA
- Ω=X1/X10/X100/X1K/X10K(Mid scale 20)
- dB=-10-+22dB
- hFE=0-1000 (W/TR CONNCOTOR)
- Sensitivity=DC 20KΩ/V,AC9KΩ/V
- Accuracy=DCV,DCmA:±3% f.s. DCA,ACV,Ω:±5% f.s.
- Size=145X98X35mm
- Weigh=220g
- Continuity check with buzzer or LED indicator
- Box:GTY:40PCS N.W.:14KGS G.W.:15KGS M:44*33*28cm |
|
|
|
GLB-960TR
- Excellent DC resolution factor of 2mV and expanded resistance measurement from 0.2Ω to 20MΩ. .
- Series capacitor terminal(OUTPUT)blocks DC to enable measurement of only AC components.
- A large and bright meter with a scale length of 80mm and its sensitivity of 44μ A at full scale.
- Fuse and diode protection.
- Measures hFE of transistor directly.
- DCV=100m/500m/2.5/10/50/250/1000v(20kΩ/V)±3%f.s.25kV(with Hvprobe)
- ACV=10/50/250/1000v(9kΩ/V)±4%f.s.
- DCA=50μ/2.Sm/25m/250mA±3%f.s.(2.5A,10A±5%f.s.)
- Ω=2/20k/200k/2M/20mΩ MAX±3% of arc.
- dB=-10-62dB
- Ll=150μ/1.5m/15m/150mA
- hFE=0-1000(w/TR conncetor)
- Power source=R6(1.5V)X2,6F22(9V)X1
- Size.weight=150XI00X36mm.280g |
|
|
|
GLB-960TRE
- Excellent DC resolution factor of 2mV and expanded resistance measurement from 0.2Ω to 20MΩ.
- Series capacitor terminal(OUTPUT)blocks DC to enable measurement of only AC components.
- A large and bright meter with a scale length of 80mm and its sensitivity of 44μ A at full scale.
- Fuse and diode protection.
- Measures hFE of transistor directly.
- DCV=100m/500m/2.5/10/50/250/1000v(20kΩ/V)±3%f.s.25kV(with Hvprobe)
- ACV=10/50/250/1000v(9kΩ/V)±4%f.s.
- DCA=50μ/2.5m/25m/250mA±3%f.s.(2.5A,10A±5%f.s.)
- Ω=2k/20k/200k/2M/20m Ω MAX±3% of arc.
- dB=-10-62dB
- L1=150μ/1.5m/15m/150mA
- hFE=0-1000(w/TR conncetor)
- Power source=R6(1.5V)X2,6F22(9V)X1
- Size.weight=150X100X36mm.280g |
|
|
|
GLB-1109
- Range:DCV:0.1-0.5-2.5-10-50-250-1000V ACV:10-50-250-1000V
- DcmA:O.O5-2.5-25-250mA
- AcA:15A
- Ω:X1,X10,X1K,X10K
- dB:-10-+22dB
- Sensitivity:DC 20KΩ/V,AC 9KΩ/V
- Accuracy:DC:±3% F,S AC Ω:±5% F,S
- Size:160X98X45mm
- Weight:250g |
|
|
|
|
|